Language: English ชื่อชุด: Misc. Invest. no. 86 Rep. no. 2ข้อมูลการพิมพ์: Bangkok : Thailand Institute of Scientific and Technological Research, 1976 รายละเอียดตัวเล่ม: 4 p.หัวเรื่อง: Arc welding | Electrodes | Steelสารสนเทศออนไลน์: Click here to access full-text สาระสังเขป: Previous tests on weld-metal prepared from locally produced welding electrodes made with G.S. steel core wire have shown tensile strength exceeding the upper limit called for in the Thai Industrial Standard Specification TIS 49-2516. An attempt has been made to decrease the tensile strength by lowering the carbon content of the steel core wire to about 0.07 per cent. The results indicate that by lowering the carbon content, the strength can be reduced but it still exceeds the maximum limit by a small margin (2 kg/mm ). All the other properties of the weld-metal, however, conform to the TIS Specification Authors.