Assessment of the performance of dry cells / Kasem Balajiva, Sombhob Tantivichekit and Precha Photiyarat

โดย: Balajiva, Kasem
ผู้แต่งร่วม: Photiyarat, Precha | Tantivichetkit, Sombhob | Thailand Institute of Scientific and Technological Research
Language: English ชื่อชุด: Res. Proj. No. 6/3 Rep. No. 2ข้อมูลการพิมพ์: Bangkok : Thailand Institute of Scientific and Technological Research, 1967 รายละเอียดตัวเล่ม: 14 p.หัวเรื่อง: Dry cellsสารสนเทศออนไลน์: Click here to access full-text สาระสังเขป: A satisfactory battery testing equipment has been designed for testing cells both under the proposed Thai National Standard Specification and the American Standards Association Specification ASA Cl8.1-1959. The results of tests on a number of experimental cells of varying quality suggest that the proposed Thai test is less sensitive to variation in cell performance than the American test and the latter test is more suitable for further studies on evaluation of manganese ores for dry cell depolarizer. Since certain cells can meet the Thai specification but fail to fulfil the requirements of the ASA specification, the proposed Thai test should not be employed to quality cells which may be used in areas where American specifications are the accepted standards. Authors