Premature fracture in ribbed reinforcement bars / Kasem Balajiva, L. S. Knudsen

โดย: Balajiva, Kasem
ผู้แต่งร่วม: Knudsen, L.S.
Language: English ชื่อชุด: Misc. Invest. no. 46 Rep. no.1ข้อมูลการพิมพ์: Bangkok : TISTR, 1971 รายละเอียดตัวเล่ม: 6 p.หัวเรื่อง: Construction materials | Fractures (materials) | Reinforcement bars | Steelสารสนเทศออนไลน์: Click here to access full-text สาระสังเขป: A local steel manufacturer producing ribbed reinforcement bars found a substantial amount rejected by customers due to cracks and fracture of the bars upon restraightening before use. Investigation showed that the failure was caused by interaction between a too high tin content, which increased the notch sensivity, and the undercut at the base of each rib. The effect is probably accentuated by a relatively high carbon content. If these unfavorable conditions are avoided, no failure are believed to occur. Authors